EN

EN

product page banner
Ledes ENT Conduit Electrical Nonmetallic Tubing Flexible Pipe Raceway Conduit UL & CSA Certified PVC Piping – Blue
Ledes ENT Conduit Electrical Nonmetallic Tubing Flexible Pipe Raceway Conduit UL & CSA Certified PVC Piping – Blue
Ledes ENT Conduit Electrical Nonmetallic Tubing Flexible Pipe Raceway Conduit UL & CSA Certified PVC Piping – Blue
Ledes ENT Conduit Reels Package Electrical Nonmetallic Tubing PVC Pipe Brand Manufacturer Wholesaler Supplier Price

Ledes CSA Certified Electrical Nonmetallic Tubing Flexible Conduit

Compatible Standard

CSA C22.2  NO. 227.1 with FT4 Rating

UL 1653

Ledes - CSA Certified DB2 ES Rigid PVC Conduit Supplier

Features

CSA & UL Certified. Ledes ENT flexible conduit pipe & fittings are proudly CSA & UL certified, ensuring a safe and reliable electrical connection. Get in touch with us today for more information and discuss your project requirements.

Concrete Tight. Ledes is a leading provider of high-performance concrete and underground solutions. We craft optimal product formulations and processes to ensure unparalleled strength and durability. With our quick-connect fittings, resolving issues is a breeze—making it easy to get the job done quickly and efficiently.

Impact Resistant. Up to 2.7J (2.0ft-lbf) anti-impact won’t crack or break during installation.

Exceptional Fire Resistance. Brand-new flame-retardant materials and state-of-the-art processes ensure fire-resistant floor and ceiling assemblies that exceed the rigorous standards of FT4 and UL94.

Durable and Flexible. Strong as a pull of up to 170 pounds, yet remarkably flexible, this tool is easy to bend by hand without any tools, making it super user-friendly.

Trusted Partner. With 15+ massive construction projects under our belt, we’re a core supplier to 1,000+ companies across the US, CA, AU, UAE, and SA.

Overview

Ledes Electrical Non-Metallic Tubing (ENT) is a corrugated flexible conduit used for electrical raceways, which is designed to replace EMT, flexible metal conduit, or other raceway systems in accordance with Article 331 of the National Electrical Code. It can be installed in concrete slabs, fire-rated interior walls, directly buried, and buildings.
Any ENT used shall meet the requirements of UL 1653 and NEMA TC-13 and shall be listed by Underwriters Laboratories, Inc.

Ledes nonmetallic flexible pipes can perfectly solve the long-term concrete-wrapped and wet underground environment and can also be used to construct ceilings and walls.

The Ledes ENT electrical conduit series offers a plethora of advantages, making it the perfect choice for home decoration, schools, hospitals, government projects, and a wide range of other scenarios. Its lightweight and convenient design make installation a breeze, and its anti-corrosion properties ensure that it will withstand the test of time, eliminating rust altogether.

Whether you are a homeowner, contractor, or builder, the Ledes ENT electrical conduit series is the ideal solution to elevate your construction project to new heights. Not only does it significantly enhance the quality of construction projects, but it also significantly reduces labor costs, making it an economically savvy choice.

Therefore, ditch the metal conduit and choose the Ledes ENT electrical conduit series today and experience the many benefits for yourself.

As a leading supplier of PVC electrical conduit pipes in China, Ledes has been shaping the industry for over 14 years. With their unmatched CSA certified & UL Certified electrical pipe products and accessories, Ledes stands as the 1st manufacturer in China to achieve this prestigious recognition.

Contact Ledes to get claim your free sample today!

Product Description

Why You Need CSA & UL Listed Electrical Nonmetallic Tubing?

Design for CA & US Market

Ledes electrical nonmetallic tubing and accessories offer industry-leading strength, with up to 4,448N Anti-Bend and 170 lbs pull resistant. We have a team of experienced designers who are adept at crafting a wide range of electrical conduits and fittings. Adherence to standards like CSA, UL, and NEMA is paramount in the development of our products.

Branded Product

Our premium ent conduit made of brand-new materials eliminates the need for pre-installation time and cost savings, making it the perfect choice for quick and easy installations.

High Fire Rating

Ledes ENT tubing with FT4 & UL 94V-0 fire rating self-extinguishes in 5 seconds after cutting off the fire source, significantly enhancing the safety of life and property.

Non - Metallic Conduit

Despite being lightweight and cost-effective, plastic electrical conduit can also be rust-proof and insulated. However, after long-term use, wires encased in plastic conduit can corrode and rust, posing a potential safety hazard to individuals.

Easy Installation & Maintenance

The ENT flexible pipe is super bendable without requiring any special tools, making it easier to pull wiring wherever you need. Additionally, with its quick assembly fittings, maintenance is a breeze, saving you time and money.

Performance

Impact Resistant

2.7J (2.0ft-lbf)

Anti-Bend

Up to 4,448N (1000 lb),   No Cracked

Pull Resistant

Up to 170 lbs

Markings Test

No visible fading in oven test above   120°C for 7 days

Fire Resistant

FT4 & UL94 V-0

Concrete Tight

CSA & UL Approved

Tension Test

Up to 134N (300lbf)

Permanency of Printing

Yes

Rust   & Sunlight Resistant

Yes

Color

Grey, Blue,   Red, Yellow or Customized

Material

PVC

Customized Services

Available 

Place of   Origin

Dongguan, China

Shipping

By sea

Samples

Available

Length

By Pack

 

 

Markings

The following should be clearly and permanently marked on the ENT tube at intervals of not more than 1.5 m (60 in):

content:

a) the manufacturer’s name, trademark or other recognized identifier;

b) “ENT” type;

c) construction material “PVC”;

d) Metric and Imperial dimensions, such as 16 (1/2);

e) “FT4” when tested according to clause 7.3; CSA C22.2 NO.227.1-06 UL 1653 21

f) production code (date of manufacture);

g) “for residential attics 900 mm (3 ft) above the bottom of the ceiling joists” when the ENT material complies with clause 4.1.4;

h) In the United States, when the manufacturer has multiple plants producing electrical non-metallic bellows, identify the production plant. In Canada, subparagraph (h) does not apply.

i) In Canada, trade size 63 (2-1/2) should be marked “Canada Only”.

 

 

The smallest package of finished cut lengths, rolls or reels shall be marked with:

a) the manufacturer’s name, trademark or other recognized identifier;

b) “ENT” type;

c) construction material “PVC”;

d) Metric and Imperial dimensions, such as 16 (1/2);

e) the total length of the product in the package;

f) the manufacturer’s instructions for fixing the solvent connection fittings (this mark may appear on the packaging or in the accompanying booklet);

g) “For residential attics 900 mm (3 ft) above the bottom of the ceiling joists” when the electrical non-metallic bellows material complies with Section 4.1.4.

h) In Canada, trade size 63 (2-1/2) should be marked “Canada Only”.

Properties

Ledes ENT Tube Dimensions

 

 

 

Size(in)

Part No.

Avg. OD(in)

Avg. ID(in)

Length per Coil

1/2

LE-ENTCA01

0.840

0.602

100ft.

3/4

LE-ENTCA02

1.050

0.804

100ft.

1

LE-ENTCA03

1.315

1.029

100ft.

1-1/4

LE-ENTCA04

1.660

1.360

100ft.

1-1/2

LE-ENTCA05

1.900

1.590

100ft.

2

LE-ENTCA06

2.375

2.047

100ft.

2-1/2

LE-ENTCA07

2.866

2.469

100ft.

 

Remarks: can be customized thickness and color

2-1/2 size for Canada only.

Standards

Purpose

Price List

Get the full price list now by contact our sales team.

Learn More about This Products